Audit ST-1 Shot TimerSale ✓
Rental ✘
Rental ✘
To maintain product quality it is important that every aspect of an inspection system is monitored regularly. ln particular the performance of an MPI system
is dependent on a number of parameters, each of which must be within acceptable procedural limits. Where magnetizing equipment is fitted with a timer to control shot duration, it must be calibrated on a regular basis, usually to an accuracy within ± 0.1 sec.
- Is a precision hand-held electronic timer specifically designed to check timer controls fitted to MPI benches.
- Has a resolution of 0.02sec and is able to make accurate measurement of the duration of a magnetizing shot in respect of AC, HWDC and FWDC waveforms.
- Operates equally for current flow, coil and flux flow magnetizing methods.
- Can accommodate dual shots, recording both the first and second shot times and the duration of the rest interval.
- Is fully calibrated using equipment traceable to National Standards.